Introduction:BPA is a non biodegradable antioxidant that has greatly hazardous for human and animals health. and Because of the eliminating alone fewness amount of the BPA during the wastewater treatment, wastewater that contains BPA can be source of pollution in aqueous solution. The objective of this study was Performance of ultrasonic and H2O2 technologies in removal of BPA from aqueous solution.
Methods:Experiments of sonochemical was carried out with use of unit ultrasonicator (Elma), which in the two power 300 and 500W, frequencies at 35 and 130KHz. Hydrogen Peroxide in concentrations at 5, 15 and 30mg/lit was applied. Initial concentration BPA at limits 2, 5, 20 and 50 mg/lit which For measuring concentration of BPA used from Spectrometer UV/VIS Lambada 25 Perkin Elmer, Shelton unit.
Results:The results demonstrated that hybrid ultrasonic and peroxide Hydrogen processes with Efficiency 98.65%, has the highest efficiency in the removal of BPA. The most decomposition rate achieved at the frequency of 130 KHz and 500W assisted by 30mg/lit H2O2 at pH 11. Also the results demonstrated that with pH increase destruction rate BPA the increased by any three processes (ultrasonic, H2O2 and both hybrid).
Conclusion:The results demonstrated that hybrid ultrasonic and peroxide Hydrogen processes can be used as a clean method and friendly environment for waters treatment are contains desirable BPA.