<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Tolooebehdasht</title>
<title_fa>طلوع بهداشت</title_fa>
<short_title>TB</short_title>
<subject>Medical Sciences</subject>
<web_url>http://tbj.ssu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1728-5127</journal_id_issn>
<journal_id_issn_online>2538-1598</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>11</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1391</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2012</year>
	<month>6</month>
	<day>1</day>
</pubdate>
<volume>11</volume>
<number>1</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه اثر ضدعفونی کنندگی اشعه ماوراءبنفش و ماده شیمیایی کورنکس بر سطوح اتاقهای عمل بیمارستان سوختگی شهید صدوقی یزد</title_fa>
	<title>The Effects of UV C Light and Cornex for Disinfection of Surfaces in Yazd Shahid Sadughi Burn Center</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p&gt; &lt;strong&gt; سابقه و اهداف &lt;/strong&gt;: برای جلوگیری از پخش عوامل بیماری زا در محیط بیمارستان روشهای بهداشتی مناسبی برای ضدعفونی سطوح آلوده لازم است. یکی از روشها استفاده از مواد شیمیایی است که وقت گیر و زحمت دار بوده و برای کارکنان و محیط هم مضر است. تحقیقات در مورد روشهای مختلف ضدعفونی سالهای زیادی است که انجام می شود. نور UVC (100 تا 280 نانومتر) برای ضد عفونی آب، روی سطوح و هوا استفاده می شود ولی دوز کشنده لازم برای میکروبهای مختلف متفاوت است. در این تحقیق دوز حاصل از لامپهای UVC موجود در اتاقهای عمل بیمارستان سوختگی شهید صدوقی یزد (با طول موج nm 254) اندازه گیری و میزان ضد عفونی کنندگی آن با ماده شیمیایی کورنکس مقایسه گردید. &lt;/p&gt;&lt;p&gt; &lt;strong&gt; روش بررسی: &lt;/strong&gt;&lt;strong&gt;&lt;/strong&gt;این مطالعه به روش توصیفی مقطعی انجام گرفت. میزان تابش رسیده به قسمتهای مختلف اتاق با تقسیم بندی کف اتاقها بفواصل Cm 50 در ارتفاع 80 سانتیمتر بعد از 14 ساعت روشن بودن لامپها اندازه گیری شد. همچنین میزان تابش UVC در محل های خاصی که از پیش تعیین شده بود(15 محل) مانند روی میز، روی تخت، داخل قفسه و ... نیز اندازه گیری شد. نمونه های میکروبی از سطوح اتاقهای عمل قبل و بعد از تمیز کردن استاندارد بیمارستان، تابش UVC و ضدعفونی کننده کورنکس برداشته شد. نمونه ها با استفاده از پلیت های تماسی استاندارد جمع آوری شده و با یکدیگر مقایسه گردیدند.&lt;strong&gt;&lt;/strong&gt; &lt;/p&gt;&lt;p&gt; &lt;strong&gt; یافته ها: &lt;/strong&gt;نتایج نشان داد که دوز رسیده به قسمتهای مختلف کف اتاقهای عمل بین صفر تا 37951 ژول بر متر مربع بوده است. آزمایشات نشان داد که UVC تعداد کلونی ها را روی سطوح اتاق های عمل ، از متوسط cfu/sample 80/64 به cfu/sample 67/41 تقلیل میدهد و بعد از ضدعفونی اضافی شیمیایی با کورنکس به cfu/sample 53/16 کاهش پیدا میکند. بنابراین مشخص گردید که استفاده از UVC و ضدعفونی کننده کورنکس به تنها یی و یا در ترکیبهای مختلف تعداد کولونی های سطحی را بطور معنی داری کاهش می دهند( برای هر دو 001/0 P&lt; ). &lt;/p&gt;&lt;p&gt; &lt;strong&gt; نتیجه گیری: &lt;/strong&gt;با توجه به نتایج بدست آمده مشخص شد که در حداقل نیمی از اتاق میزان دوز تقریبا صفر بوده ولی در نزدیکی لامپها بعلت طولانی بودن زمان استفاده ، میزان دوز حتی از میزان دوز لازم برای غیرفعال سازی مقاومترین ویروسها بیشتر است. به این ترتیب نتیجه گیری شد که بایستی در تعداد و محل نصب و زمان روشن بودن لامپهای ضدعفونی کننده UVC تجدید نظر بعمل آید و متناسب با دوز لازم استاندارد برای تمام نقاط اتاق تنظیم گردد. از طرف دیگر UVC برای ضدعفونی سطوح کاملا در سایه مانند زیر تخت موثر نیست. بنابراین نور UVC بایستی بهمراه ضدعفونی کننده های شیمیایی مورد استفاده قرار گیرد. &lt;/p&gt;  </abstract_fa>
	<abstract>&lt;p&gt; &lt;strong&gt;Background:&lt;/strong&gt; To control the spread of pathogens in hospital environments, good hygienic routines are required to disinfect surfaces contaminated with biological materials. Chemicals have traditionally been used to disinfect surfaces during final room disinfection. However, chemical disinfection is both time- and labor-consuming, and it might be harmful for staff and the environment. The search for more environmentally friendly and healthier methods has therefore been under way for many years. UVC light (200-280 nm) has germicidal effect on microorganisms in water, on surface, and in air. However, its lethal dose for various microbes is different. In this study, the dose of UVC lamps (wavelength 254 nm) in hospital operating rooms of Shahid Sadughi Burn Center were measured and its disinfectant strength was compared with a standard chemical disinfectants (Cornex).&lt;/p&gt;&lt;p&gt; &lt;strong&gt;Method: &lt;/strong&gt;In this cross-sectional descriptive study at first the UVC irradiance levels were measured after 14 houres light exposure at the outset. The distance between the measurement locations was 50 Cm and the radiometer was put on the 80 Cm height of the floor. In addition the UVC irradiance levels were measured in 15 other sites including surfaces on the table, bed, door handle, inside the rack etc. Microbial samples were obtained from surfaces in isolated units before and after standard hospital environmental cleaning, irradiation with UVC and cornex disinfection. Samples were collected using standard contact plates and were compared together . &lt;/p&gt;&lt;p&gt; &lt;strong&gt;Result&lt;/strong&gt;: The results of this study showed that the UVC detected dose was 0-37951 j/m&lt;sup&gt;2&lt;/sup&gt;. Also the results showed that UVC markedly reduced the number of bacteria on surfaces in operating rooms, from a mean of 64.80 cfu per sample to 41.67 cfu per sample after UVC disinfection and to 16.53 cfu per sample after additional cornex disinfection. So the use of UVC and of cornex disinfection alone or in different combinations significantly reduced the amount of surface contamination (P&lt; .001 for both)&lt;/p&gt;&lt;p&gt; &lt;strong&gt;Conclusion&lt;/strong&gt;: According to the results obtained, the detected dose in about half part of the locations was almost 0 j/m2, while in the places near to the lamps the detected dose was higher than the required dose for resistant virus inactivation due to long time exposure. Therefore it is concluded that the number, locations of the UVC lamps, and also the exposure time should be changed according to the standard dose for all parts of the room. On the other hand, UVC is not suitable and efficient disinfectant for the sites that are in shadow. There fore,these places must be disinfected by a combination of UVC and chemical disinfectants. &lt;/p&gt;&lt;p&gt; &lt;/p&gt;</abstract>
	<keyword_fa>اشعه ماوراء بنفش،ضدعفونی، اتاق عمل</keyword_fa>
	<keyword>Dosimetry,UV light, Disinfection, Operating room</keyword>
	<start_page>53</start_page>
	<end_page>63</end_page>
	<web_url>http://tbj.ssu.ac.ir/browse.php?a_code=A-10-1-10&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>SA</first_name>
	<middle_name></middle_name>
	<last_name>Falahati</last_name>
	<suffix></suffix>
	<first_name_fa>سیداحمد</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فلاحتی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>afalahaty@yahoo.com</email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Shahid Sadoughi University of Medical sciences Yazd, Iran</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی و خدمات بهداشتی درمانی شهید صدوقی یزد</affiliation_fa>
	 </author>


	<author>
	<first_name>MT</first_name>
	<middle_name></middle_name>
	<last_name>Noorbala</last_name>
	<suffix></suffix>
	<first_name_fa>محمدتقی </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>نوربالا</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Shahid Sadoughi University of Medical sciences Yazd, Iran</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی و خدمات بهداشتی درمانی شهید صدوقی یزد</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Malek</last_name>
	<suffix></suffix>
	<first_name_fa>مهدی</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>ملک</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Shahid Sadoughi University of Medical sciences Yazd, Iran</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی و خدمات بهداشتی درمانی شهید صدوقی یزد</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
