<?xml version="1.0" encoding="utf-8"?>
<journal>
<title>Tolooebehdasht</title>
<title_fa>طلوع بهداشت</title_fa>
<short_title>TB</short_title>
<subject>Medical Sciences</subject>
<web_url>http://tbj.ssu.ac.ir</web_url>
<journal_hbi_system_id>1</journal_hbi_system_id>
<journal_hbi_system_user>admin</journal_hbi_system_user>
<journal_id_issn>1728-5127</journal_id_issn>
<journal_id_issn_online>2538-1598</journal_id_issn_online>
<journal_id_pii>8</journal_id_pii>
<journal_id_doi>7</journal_id_doi>
<journal_id_iranmedex></journal_id_iranmedex>
<journal_id_magiran></journal_id_magiran>
<journal_id_sid>14</journal_id_sid>
<journal_id_nlai>11</journal_id_nlai>
<journal_id_science>13</journal_id_science>
<language>fa</language>
<pubdate>
	<type>jalali</type>
	<year>1392</year>
	<month>12</month>
	<day>1</day>
</pubdate>
<pubdate>
	<type>gregorian</type>
	<year>2014</year>
	<month>3</month>
	<day>1</day>
</pubdate>
<volume>12</volume>
<number>4</number>
<publish_type>online</publish_type>
<publish_edition>1</publish_edition>
<article_type>fulltext</article_type>
<articleset>
	<article>


	<language>fa</language>
	<article_id_doi></article_id_doi>
	<title_fa>مقایسه تاثیر دستگاه الکترولیز تجاری حاوی با الکتروهای آهن و آلومینیوم با الکترودهای زغالی بر کیفیت فیزیکو شیمیایی آب آشامیدنی</title_fa>
	<title>Comparison of Dual Precipitator Electrodes (with Iron and Aluminum) and Coal electrodes on physicochemical quality of water</title>
	<subject_fa>تخصصي</subject_fa>
	<subject>Special</subject>
	<content_type_fa>پژوهشي</content_type_fa>
	<content_type>Research</content_type>
	<abstract_fa>&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;مقدمه:&lt;/strong&gt; فروشندگان دستگاههای تصفیه آب در نقطه مصرف (خانگی) برای بازاریابی و افزایش فروش محصولات خود، با استفاده از الکترودهای تجاری آهن و آلومینیوم، کیفیت آب شرب را دستخوش تغییراتی نموده که باعث افزایش جامدات محلول و معلق آب می شود که با نصب تجهیزات تصفیه آب، آب خروجی زلالی تولید می شود. با توجه به عدم وجود دلایل علمی موجه در ایجاد لجن و تغییر رنگ آب ناشی از الکترولیز با الکترود تجاری، این مطالعه با هدف مقایسه کیفیت فیزیکو شیمیایی آب پس از الکترولیز با الکترودهای تجاری و الکترود زغالی(به عنوان شاهد) انجام شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;روش بررسی:&lt;/strong&gt; پس از انجام فرایند الکترولیز با الکترودهای تجاری (آهن و آلومینیم بطور توام)، هریک بطور مجزا و الکترود زغالی (به عنوان شاهد) بر روی نمونه­های آب، پارامترهای کیفی سختی، قلیائیت، &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; ، &lt;span dir=&quot;LTR&quot;&gt;EC&lt;/span&gt;،&lt;span dir=&quot;LTR&quot;&gt;TDS&lt;/span&gt;  قبل و بعد از الکترولیز به روش استاندارد مورد آزمایش قرار گرفت. پس از آنالیز داده ها، میانگین پارامترهای کیفی آب ناشی از الکترولیز الکترودهای مختلف با هم مقایسه شد.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;یافته­ها&lt;/strong&gt;: &lt;span dir=&quot;LTR&quot;&gt;pH&lt;/span&gt; نمونه­ها پس الکترولیز با الکترود تجاری و الکترودهای آهن-آهن افزایش معنی داری داشت(05/0&lt;span dir=&quot;LTR&quot;&gt;p &lt;&lt;/span&gt;) ولی با الکترودهای آلومینیوم- آلومینیوم تغییر معنی داری مشاهده نشد(05/0&lt;span dir=&quot;LTR&quot;&gt;p &gt;&lt;/span&gt;). سختی کل، کلسیم و منیزیم و قلیاییت نیز پس از الکترولیز باالکترود تجاری و الکترودهای آهن-آهن افزایش معنی داری داشت (05/0&lt;span dir=&quot;LTR&quot;&gt;p &lt;&lt;/span&gt;) ولی برای الکترودهای آلومینیوم - آلومینیوم بدون تغییر ماند. هدایت الکتریکی و کل جامدات محلول پس از الکترولیز با انواع الکترودها از نظر آماری بطور قابل ملاحظه ای افزایش یافته بود. رنگ نمونه ها پس از استفاده از الکترودهای آهن-آهن  و الکترود تجاری قرمز مایل به قهوه­ای و برای الکترودهای آلومینیوم سفید کدر شده در حالی که پس از استفاده از الکترود زغالی تغییری پیدا نکرده بود.&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;strong&gt;نتیجه گیری: &lt;/strong&gt;الکترولیز آب با الکترودهای تجاری مورد مطالعه باعث تولید رنگ و لجن در اثر آزادسازی یونهای آلومینیوم و آهن شده و منجر به تولید آبی کدر و سیاه می شود که به تصور اشتباه، ناخالصی های آب می باشد در حالی که رسوبات تشکیل شده ناشی از واکنش یونهای آزاد شده از الکترودها با هیدروکسید آب مورد آزمایش می باشد. پس این گونه الکترودها تقلبی بوده و استفاده های سودجویانه از آن می شود که مراکز بهداشت بایستی نسبت به افزایش آگاهی عموم و جمع آوری آنها از بازار اقدام نمایند. &lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt; &lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;

&lt;p dir=&quot;RTL&quot;&gt;&lt;/p&gt;
</abstract_fa>
	<abstract>&lt;p&gt;&lt;strong&gt;Introduction&lt;/strong&gt;: For marketing and selling their products, water-treatment equipment vendors use commercial iron and aluminum electrodes thereby changing the quality of water and increasing soluble and suspended solids in water. Due to the lack of scientific justification for the creation of sludge and discoloration caused by water electrolysis with commercial electrodes, this study aimed to compare the chemical water quality after electrolysis with electrodes and electrode coal trade (as a control) in order to detect trick and fraud.&lt;/p&gt;

&lt;p&gt; &lt;strong&gt;Methods:&lt;/strong&gt; After the electrolysis process with commercial electrodes (iron and aluminum combined), each electrode individually and coal (as control) on the water quality, the parameters such as hardness, alkalinity, pH, EC, TDS before and after the electrolysis were tested by standard methods. After analyzing the data, the average water quality parameters resulting from the electrolysis of various electrodes were compared.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt; Results:&lt;/strong&gt; After placing the commercial and iron-iron electrodes, pH of the samples increased significantly (p &lt;0.05) whereas after using aluminium-aluminum electrode,&lt;/p&gt;

&lt;p&gt; no significant relation was identified (p &gt;0.05). Total hardness, alkalinity, calcium and magnesium and also the trade of placing the electrode and iron electrodes increased significantly (p &lt;0.05) and aluminum electrodes and electrode placement of the trade remains unchanged. Electrical conductivity and total dissolved solids applied to the electrodes of all types were statistically significantly increased. Color samples of the iron electrode and electrode commercial red brownish and opaque white aluminum electrodes of the electrode and the coal was not changed. Except when using coal electrodes, in all cases in which sludge was produced using iron electrodes and electrode-alone commercial green color to black and opaque white was the color of coal electrodes. These results include the not be related to the water.&lt;/p&gt;

&lt;p&gt;&lt;strong&gt;Conclusion: &lt;/strong&gt;&lt;span dir=&quot;RTL&quot;&gt;Electrodes in water electrolysis with commercial production of paints and sludge dumping of aluminum and iron ions and leads to the production of opaque blue and black is wrong to assume, is water impurities. These electrodes were fake and the fostering of the use of the health center should be to increase public awareness and take action to collect them from the market.&lt;br&gt;
  &lt;/span&gt;&lt;/p&gt;
</abstract>
	<keyword_fa>واژه­های کلیدی: الکترودهای تجاری آهن و آلومینیوم, الکترود زغالی, کیفیت آب</keyword_fa>
	<keyword>Keywords: iron and aluminum electrodes, coal electrodes, water quality</keyword>
	<start_page>117</start_page>
	<end_page>124</end_page>
	<web_url>http://tbj.ssu.ac.ir/browse.php?a_code=A-10-1-202&amp;slc_lang=fa&amp;sid=1</web_url>


<author_list>
	<author>
	<first_name>H</first_name>
	<middle_name></middle_name>
	<last_name>Farrokhzadeh</last_name>
	<suffix></suffix>
	<first_name_fa>حسین</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فرخ زاده</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name>H</first_name>
	<middle_name></middle_name>
	<last_name>Hashemi</last_name>
	<suffix></suffix>
	<first_name_fa>حسن</first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>هاشمی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email>hashemi@hlth.mui.ac.ir </email>
	<code></code>
	<orcid></orcid>
	<coreauthor>Yes
</coreauthor>
	<affiliation>Shahrekord University of Medical Sciences, Shahrekord, Iran </affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی شهرکرد </affiliation_fa>
	 </author>


	<author>
	<first_name>MM</first_name>
	<middle_name></middle_name>
	<last_name>Amin</last_name>
	<suffix></suffix>
	<first_name_fa>محمد مهدی </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>امین</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی اصفهان</affiliation_fa>
	 </author>


	<author>
	<first_name>M</first_name>
	<middle_name></middle_name>
	<last_name>Foroughi </last_name>
	<suffix></suffix>
	<first_name_fa>مریم </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>فروغی</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Hamedan University of Medical Sciences, Hamedan, Iran</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی همدان </affiliation_fa>
	 </author>


	<author>
	<first_name>N</first_name>
	<middle_name></middle_name>
	<last_name>Jafari </last_name>
	<suffix></suffix>
	<first_name_fa>نگار </first_name_fa>
	<middle_name_fa></middle_name_fa>
	<last_name_fa>جعفری</last_name_fa>
	<suffix_fa></suffix_fa>
	<email></email>
	<code></code>
	<orcid></orcid>
	<coreauthor>No</coreauthor>
	<affiliation>Isfahan University of Medical Sciences, Isfahan, Iran</affiliation>
	<affiliation_fa>دانشگاه علوم پزشکی اصفهان</affiliation_fa>
	 </author>


</author_list>


	</article>
</articleset>
</journal>
