Volume 14, Issue 4 (11-2015)                   TB 2015, 14(4): 11-22 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Ehrampoosh M, ZareSakhvidi M, Mehrparvar A, fallahzadeh H, Soltanianzadeh Z, Gamshidi S et al . Evaluating Suspended Particles Concentration of the Inside and Outside Air of the Classroom and Its Influencing Factors in Middle schools and High Schools of Yazd. TB 2015; 14 (4) :11-22
URL: http://tbj.ssu.ac.ir/article-1-1773-en.html
Shahid Sadoughi University of Medical Sciences, Yazd , sara.jamshidi64@gmail.com
Abstract:   (4709 Views)

Abstract

Introduction: Airborne pollution in such public environments as schools has adverse health effects on pupils and teachers who spend a noticeable amount of time in the school. Therefore, this study aimed to measure the suspended particles concentration of indoor and outdoor air of Yazd schools as well as to determine the influencing parameters on the pollution intensity.

Methods: This analytical cross-sectional study was conducted in 20 middle-schools and high schools of males and females in winter of 2013. The environmental aerosol monitoring device, (HAZ-DUST EPAM5000 model) was used to measure the concentration of PM1, PM2.5 and PM10. The study data were analyzed via applying correlation, simple linear regression and means comparison tests. Moreover, the study results were compared with the standards of World health organization(WHO) and Environmental Health Organization(EPA).

Results: The mean concentration of PM10, PM2.5 and PM1 in indoor class air was reported higher compared to the outdoor air. The indoor and outdoor air quality of schools in terms of Air Quality Index9 (AQI Calculator) indicated an average condition for PM10, and an unhealthy condition for PM2.5 in regard with the vulnerable groups. A significant relationship was detected between indoor and outdoor air concentration particles (P<0.05). The mean indoor per outdoor air particles ratio (I/O) was 1.68, 1.31, 1.46 respectively for PM10, PM2.5, PM1.

Conclusion: The study findings revealed a significant relationship between indoor and outdoor suspended particle concentration demonstrating the particles penetration into the classrooms. Therefore, utilizing appropriate air conditioner systems are regarded effective in order to mitigate indoor class pollution.  

Full-Text [PDF 225 kb]   (1739 Downloads)    
Type of Study: Applicable | Subject: Special
Received: 2015/11/17 | Accepted: 2015/11/17 | Published: 2015/11/17